Water quality, flow and level instruments for STP, ETP and pharma +91 99638 85957 sales@senvolt.com

ETP Instrumentation

Industrial effluent varies with production and often contains acids, alkalis, oils and metals. ETP instruments must survive the chemistry and give operators the readings they need to keep the outlet within limits.

Instruments for each stage of an ETP

StageWhat to measureRecommended instrument
Collection and equalisationLevel, pHRadar level transmitter, pH controller PH101
NeutralisationpHpH controller with acid/alkali dosing relays
Chemical treatmentORP (cyanide, chrome)ORP controller ORP101
Effluent transferFlowPTFE-lined electromagnetic flow meter
Oil separationOil in waterOil in water sensor
Final outletCOD, BOD, TSS, pH, flowOnline continuous effluent monitoring system

Frequently asked questions

Which lining should I choose for an ETP flow meter?

PTFE or FEP linings resist almost all acids and alkalis. The electrode metal must also match the effluent – see the lining and electrode selection tables on the ETP flow meter page.

Can the online monitoring system send data to both CPCB and SPCB?

Yes. The on-board gateway transmits to CPCB/SPCB servers and the Senvolt cloud dashboard simultaneously, without a separate PC.

ETP Instrumentation

Tell us what you need to measure

Share the parameter, medium, pipe size and the output your PLC or monitoring system expects. We will reply with the right model and a quotation.

We reply within one working day. Your details are used only to answer this enquiry.